Part number GL-E224-ADOC 0413






GL
Indirect-Fired Water Heaters
This manual must only be used by a qualified heating
installer/service technician. BEFORE installing, read
all instructions in this manual and all other informa-
tion shipped with the water heater. Perform steps in
the order given. Failure to comply could result in
severe personal injury, death or substantial property
damage.
 Read important user safety information
found on page 3, page 24 and page 25. Installation
and service should only be performed by a qualified
service technician. Retain this manual for future
reference.
®
Vedere la pagina 0
1 2 3 4 5 6 ... 43 44

Sommario

Pagina 1 - 

Part number GL-E224-ADOC 0413GLIndirect-Fired Water Heaters This manual must only be u

Pagina 2 - Contents

Model GL indirect-fired water heaters — Product ManualRecirculation (continued)Components1. Little flow is required to m

Pagina 3 - Please read before proceeding

Model GL indirect-fired water heaters — Product Manual Zoning with circulators — direct-connected system pipingNotes• Place circulators at

Pagina 4 - Pre-installation

Model GL indirect-fired water heaters — Product ManualBoiler-side piping (continued) Zoning with circulators — primary/secondary system pipi

Pagina 5

Model GL indirect-fired water heaters — Product ManualBoiler-side piping (continued) Zoning with zone valves — direct-connected system pipin

Pagina 6 - Domestic water piping

Model GL indirect-fired water heaters — Product ManualBoiler-side piping (continued) Zoning with zone valves — primary/secondary system pip

Pagina 7

Model GL indirect-fired water heaters — Product ManualBoiler-side piping (continued) Dedicated single-boiler pipingNotes• Place circulator

Pagina 8

Model GL indirect-fired water heaters — Product ManualBoiler-side piping (continued) Multiple water heaters — domestic water piping

Pagina 9

Model GL indirect-fired water heaters — Product ManualBoiler-side piping (continued) Multiple water heaters and dedicated multiple boilers

Pagina 10 - Recirculation

Model GL indirect-fired water heaters — Product ManualConnecting to a low-pressure steam boilerSpecial considerationsWhen designing steam and domesti

Pagina 11 - Boiler-side piping

Model GL indirect-fired water heaters — Product ManualConnecting to a low-pressure steam boiler (continued) Low pressure steam boiler appli

Pagina 12

Model GL indirect-fired water heaters — Product ManualContents When servicing water heater . . . . . . . . . . . . .

Pagina 13

Model GL indirect-fired water heaters — Product ManualBoiler-side wiring and controls  — Can cause severe personal injury, de

Pagina 14

Model GL indirect-fired water heaters — Product ManualWiring — zoning with circulatorsNotes• Also refer to the zone con-troller manual for further d

Pagina 15

Model GL indirect-fired water heaters — Product ManualWiring — zoning with zone valvesNotes• Also refer to the zone con-troller manual for further d

Pagina 16

Model GL indirect-fired water heaters — Product Manual The installation and water chemistry must meet the requirements below. Failure to comply coul

Pagina 17

Model GL indirect-fired water heaters — Product Manual Hot Water Can Scald!• Water heated to temperature for clothes washing, dish washing and other

Pagina 18 - Special considerations

Model GL indirect-fired water heaters — Product ManualWater heater maintenance Boiler water — read and comply with all requirements under “Boiler wa

Pagina 19 - Filling the piping

Model GL indirect-fired water heaters — Product ManualWater heater maintenance (continued)and their frequencies, including any not listed in the foll

Pagina 20 - Field wiring terminal block

Model GL indirect-fired water heaters — Product ManualTroubleshootingPreparation for troubleshootingTools needed Electrical meter to measure voltage

Pagina 21 - Part number GL-E224-ADOC 0413

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)Insufficient hot water Undersized water heater? Boiler system imp

Pagina 22

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)1 Undersized water heater? • There are many methods of sizing vari

Pagina 23

Model GL indirect-fired water heaters — Product ManualPlease read before proceeding Failure to adhere to the guidelines on this page can result in s

Pagina 24 - Setting the thermostat

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)• Is the circulator between the boiler and the water heater properl

Pagina 25 - Water heater maintenance

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)4 Check boiler operating temperatures. • If possible, increase the

Pagina 26

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)Excessive domestic water temperature1 Reduce stacking. • Excessive

Pagina 27 - Troubleshooting

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)Boiler relief valve lifting or weeping1 Undersized expansion tank?

Pagina 28

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)Temperature/pressure relief valve lifting or weeping1 Undersized or

Pagina 29

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)Water on the floor near the tank1 Check for leaks from sources other

Pagina 30

Model GL indirect-fired water heaters — Product ManualTroubleshooting (continued)Rapid decay of magnesium anode1 Anodes last less than two years T

Pagina 31

Model GL indirect-fired water heaters — Product ManualWater quality problems1 Water smells like “rotten eggs.” • The most common cause of water to

Pagina 32

Model GL indirect-fired water heaters — Product Manual• This is similar to the reaction that occurs as air bubbles form on the walls of a pan shortl

Pagina 33

Model GL indirect-fired water heaters — Product Manual  1Magnesium anode replacement kit (inclu

Pagina 34

Model GL indirect-fired water heaters — Product ManualPre-installation Clearance recommendationsCodes1. Installation must conform with inst

Pagina 35

Model GL indirect-fired water heaters — Product ManualAHRI ratings

Pagina 36

Model GL indirect-fired water heaters — Product ManualRatings with 200°F boiler supply water For water heater to achieve the rated performance below

Pagina 37

Model GL indirect-fired water heaters — Product ManualRatings with 190°F boiler supply water For water heater to achieve the rated performance below

Pagina 38

Model GL indirect-fired water heaters — Product ManualRatings with 180°F boiler supply water For water heater to achieve the rated performance below

Pagina 39 - Replacement parts

Model GL indirect-fired water heaters — Product ManualDimensions Dimensions and ratings — Model GL indirect-fired water heaters

Pagina 40 - AHRI ratings

Model GL indirect-fired water heaters — Product ManualPre-installation (continued) Hot Water Can Scald!• Water heated to temperature for clothes was

Pagina 41 - DHW 50°F to 115°F

Model GL indirect-fired water heaters — Product ManualDomestic water piping DHW pipingPiping overview   — If a backflo

Pagina 42

Model GL indirect-fired water heaters — Product ManualDomestic water piping (continued)LEGEND for Figure 2, page 6 Domestic water supplied to fixture

Pagina 43

Model GL indirect-fired water heaters — Product ManualRecirculation  applications require recircu-lation piping or heat-traced pip

Pagina 44 - Dimensions

Model GL indirect-fired water heaters — Product ManualRecirculation (continued) Time lag to obtain hot water at fixture for branch lengths of

Commenti su questo manuale